Shorter wait
The pump speeds up the flow of hot water to the tap as soon as you turn it on. No more running cold water down the drain.
Hot water circulation controller
ET1
Hot water as soon as you turn on the tap
Patent-protected solution
List pricePLN 1,050incl. VATThe ECOTECHNIK ET1 controller runs your hot water circulation system so that it adapts to the individual needs of everyone in the household.
It shortens the wait for hot water at the tap in the most economical way, while keeping everyday comfort. The circulation pump starts the moment water is drawn and replaces the cooled water in the pipes with hot water - at a temperature you set yourself.
ET1 is an original ECOTECHNIK design. The solution is protected by a patent.
Watch the ET1 film
Circulation running non-stop heats the pipes around the clock. ET1 switches it on only when it makes sense.
The pump speeds up the flow of hot water to the tap as soon as you turn it on. No more running cold water down the drain.
The controller responds to your habits, not to a schedule. There is no need to predict when you will need hot water.
It saves energy, water and the circulation pump itself, which runs for shorter periods and wears out more slowly.
Most hot water use starts with a short, small draw. For ET1 this is the signal that you need hot water.
To wet your toothbrush before brushing, the soap before washing your hands or your razor.
The sensor on the cold water supply detects the draw. Water does not have to circulate beforehand - on average you use only 3-5 litres in that time.
ET1 starts the circulation pump, which speeds up the flow of hot water to the tap. Water in the loop returns to the water heater.
The water warms up during circulation. You set the circulation temperature between 30 and 50°C.
When the set temperature is reached or after the set run time. If the loop is already warm, the pump does not start - this limits heat losses.
A smart, eco-friendly solution for all hot water circulation systems - in houses, apartment blocks and commercial premises.
The controller has all the functions needed to adapt to different hot water circulation systems.
The pump starts when the sensor detects a water draw and the loop temperature is below the set value.
Control of the set temperature in the circulation branch with adjustable hysteresis.
30-50°C, hysteresis 0.5-2°CYou set how long the pump runs after a signal from the flow sensor. Reaching the temperature earlier can cut this time short.
The limit temperature sensor starts the pump when the water heater overheats, e.g. in solar systems.
80-100°C, hysteresis 2-20°CRunning the pump periodically protects the rotor from seizing after a long idle period.
every 1-14 daysForced pump operation for 24 h, synchronised with thermal disinfection of the hot water heater.
24 hSwitch the pump on manually to test the system. It switches off automatically after 1 h.
1 hChoice of menu language and temperature units °C / °F. Settings are retained after a power cut.
The main screen shows the current temperature and the circulation temperature. While the pump is running, the controller shows the remaining run time and indicates water flow.


ET1 works with, among others, a hot water storage cylinder, a combi boiler, an instantaneous water heater and a heat interface unit. Click a diagram to enlarge it (labels in Polish).
| Supply voltage | 230 V ±10% / 50-60 Hz |
|---|---|
| Pump output load | 150 VA / 230 V |
| Operating temperature | 5-50°C |
| Ambient humidity | 5-80% RH, non-condensing |
| Temperature sensors | KTY, -30 to 120°C |
| Fuse | 1.6 A |
| Flow sensor | brass body, 2 x ¾" tapered male thread |
| Housing dimensions | 159 x 92.8 x 41 mm |
| Mounting | wall-mounted, hole spacing 100 mm |
| Warranty | 24 months |
| Protection | patent-protected solution |
The controller is wall-mounted using the wall plugs supplied. Click the wiring and flow sensor drawings to enlarge them. The circulation pump is not included - it is purchased separately.
The set: ET1 controller, water flow sensor and 2 temperature sensors. The list price of the set is PLN 1,050 incl. VAT. For businesses and larger orders we will prepare an individual quote. Click "Buy now" and leave your contact details.
1,050PLNincl. VAT
includes 23% Polish VAT · set with sensorsIndividual quote
depends on the number of controllers ordered
Patent-protected solution
We welcome installers, wholesalers and manufacturers as partners. Terms are agreed individually and depend on the number of controllers ordered.
Do you install hot water systems? Offer ET1 to your customers on wholesale terms, with technical support during installation.
Add the ET1 controller to your range. We will prepare terms matched to your order volumes.
Do you make boilers, cylinders, pumps or other heating equipment? Let's talk about working together on ET1.
The body has 2 tapered ¾" male threads - seal them using any method that gives a tight joint. Use tools that will not damage the brass body. Once the body is installed, fasten the electronic sensor with two M3 screws.
Make sure no thread sealant gets inside the sensor or the filter - this can slow down the controller's response.
On the bottom of the housing there is a 230 V switch, an F 1.6 A fuse and 5 cables:
The controller comes with factory-connected cables. Before connecting it to the mains, connect the marked cable to the circulation pump supply (following the pump manufacturer's instructions), stripping the insulation from the wire ends first. The maximum pump output load is 150 VA.
Installation should be carried out by a suitably qualified person and confirmed with an entry in the warranty card.
The range is 30-50°C, factory setting 38°C, hysteresis 1°C. Example: at 38°C with 1°C hysteresis the pump will start (after flow is detected) when the temperature drops below 37°C. For poorly insulated or long pipework, set a longer pump run time or a higher circulation temperature.
At least once a year check the condition of the device and that the cables are connected correctly. Unplug the controller during thunderstorms - lightning can damage it.
Check the pressure in the hot water expansion vessel and the flow.
Cause: faulty sensor, short circuit or break in the sensor wires, faulty controller board.
Solution: replace the sensor, check its wires and connection in the controller terminal block. In an emergency the sensor can be disabled in the menu - the controller then works according to the set run time.
Cause: faulty sensor or break in the wires, faulty controller board.
Solution: replace the sensor, check its wires and connection in the controller terminal block. In an emergency the sensor can be disabled in the menu - all other functions keep working.
When reporting a problem, give the controller software version (menu: Information). Service enquiries: sterownikcyrkulacjicwu@gmail.com, +48 790 720 126.
KOCIOŁEK C.O. of Lublin, Poland, provides a 24-month warranty for correct operation of the controller, from the date of purchase. Complaints are processed within 30 days. The warranty requires installation by a suitably qualified person, confirmed with an entry in the warranty card.
An overview of ways to control a circulation pump - from a timer to a flow sensor.
Read more
A 24-hour gas consumption measurement in a house without circulation control, plus a simple cost calculator.
Read more
How to install the flow sensor so that ET1 responds quickly and reliably.
Read moreWant to buy the controller, install heating systems or run a shop or wholesale business? Write or call us. We speak Polish and English.