Hot water circulation controllers

ECOTECHNIK Hot water circulation controller ET1

Hot water as soon as you turn on the tap

Patent-protected solution

List pricePLN 1,050incl. VAT
Good news!

Hot water faster, without circulation losses

The ECOTECHNIK ET1 controller runs your hot water circulation system so that it adapts to the individual needs of everyone in the household.

It shortens the wait for hot water at the tap in the most economical way, while keeping everyday comfort. The circulation pump starts the moment water is drawn and replaces the cooled water in the pipes with hot water - at a temperature you set yourself.

  • water flow sensor and 2 temperature sensors included
  • clear LCD display and multilingual menu
  • works with circulation pumps from different manufacturers
  • for houses, flats with a heat interface unit, apartment blocks and commercial premises

ET1 is an original ECOTECHNIK design. The solution is protected by a patent.

Watch the ET1 film
ECOTECHNIK ET1 hot water circulation controller with brass flow sensor
In a word

Time, comfort and ecology

Circulation running non-stop heats the pipes around the clock. ET1 switches it on only when it makes sense.

Shorter wait

The pump speeds up the flow of hot water to the tap as soon as you turn it on. No more running cold water down the drain.

Everyday comfort

The controller responds to your habits, not to a schedule. There is no need to predict when you will need hot water.

Economical and eco-friendly

It saves energy, water and the circulation pump itself, which runs for shorter periods and wears out more slowly.

How does it work?

Just turn on the tap

Most hot water use starts with a short, small draw. For ET1 this is the signal that you need hot water.

  1. You turn on the tap

    To wet your toothbrush before brushing, the soap before washing your hands or your razor.

  2. The flow sensor sends a signal

    The sensor on the cold water supply detects the draw. Water does not have to circulate beforehand - on average you use only 3-5 litres in that time.

  3. The pump delivers hot water

    ET1 starts the circulation pump, which speeds up the flow of hot water to the tap. Water in the loop returns to the water heater.

  4. You decide on the temperature

    The water warms up during circulation. You set the circulation temperature between 30 and 50°C.

  5. The pump switches itself off

    When the set temperature is reached or after the set run time. If the loop is already warm, the pump does not start - this limits heat losses.

  6. Fits every system

    A smart, eco-friendly solution for all hot water circulation systems - in houses, apartment blocks and commercial premises.

3-5 laverage water used before the pump needs to start
30-50°Ccirculation temperature range
24 hanti-legionella function - forced pump operation
24 monthsmanufacturer's warranty
Features

Everything a circulation system needs

The controller has all the functions needed to adapt to different hot water circulation systems.

Flow sensor control

The pump starts when the sensor detects a water draw and the loop temperature is below the set value.

Circulation temperature

Control of the set temperature in the circulation branch with adjustable hysteresis.

30-50°C, hysteresis 0.5-2°C

Adjustable pump run time

You set how long the pump runs after a signal from the flow sensor. Reaching the temperature earlier can cut this time short.

Overheating protection

The limit temperature sensor starts the pump when the water heater overheats, e.g. in solar systems.

80-100°C, hysteresis 2-20°C

Pump anti-seize

Running the pump periodically protects the rotor from seizing after a long idle period.

every 1-14 days

Anti-legionella

Forced pump operation for 24 h, synchronised with thermal disinfection of the hot water heater.

24 h

Manual mode

Switch the pump on manually to test the system. It switches off automatically after 1 h.

1 h

Multilingual menu and units

Choice of menu language and temperature units °C / °F. Settings are retained after a power cut.

ECOTECHNIK ET1 control panel with LCD display and four buttons
Easy to use

Everything at a glance on the display

The main screen shows the current temperature and the circulation temperature. While the pump is running, the controller shows the remaining run time and indicates water flow.

ET1 screen in standby
Standby - pump idle (||)
ET1 screen while the pump is running
Pump running (>) - remaining time and flow indicator
  • MENUenter the menu and confirm
  • EXITgo back and exit the menu
  • scroll, increase value
  • scroll, decrease value
Applications and diagrams

For all hot water circulation systems

ET1 works with, among others, a hot water storage cylinder, a combi boiler, an instantaneous water heater and a heat interface unit. Click a diagram to enlarge it (labels in Polish).

Hot water cylindersystem boiler with cylinder
Combi boilerinstantaneous hot water
Heat interface unitflat stations in apartment buildings
Hot water manifoldscylinder with manifold distribution
Detached houseFlatApartment buildingRestaurant and commercial premisesSolar systems
Specifications

ECOTECHNIK ET1 in numbers

Supply voltage230 V ±10% / 50-60 Hz
Pump output load150 VA / 230 V
Operating temperature5-50°C
Ambient humidity5-80% RH, non-condensing
Temperature sensorsKTY, -30 to 120°C
Fuse1.6 A
Flow sensorbrass body, 2 x ¾" tapered male thread
Housing dimensions159 x 92.8 x 41 mm
Mountingwall-mounted, hole spacing 100 mm
Warranty24 months
Protectionpatent-protected solution

Dimensions and mounting

The controller is wall-mounted using the wall plugs supplied. Click the wiring and flow sensor drawings to enlarge them. The circulation pump is not included - it is purchased separately.

Buy now

Order the ECOTECHNIK ET1 controller

The set: ET1 controller, water flow sensor and 2 temperature sensors. The list price of the set is PLN 1,050 incl. VAT. For businesses and larger orders we will prepare an individual quote. Click "Buy now" and leave your contact details.

Retail

For private customers

List price

1,050PLNincl. VAT

includes 23% Polish VAT · set with sensors
  • ET1 controller with a full set of sensors
  • 24-month manufacturer's warranty
  • technical support during installation
Wholesale

For installers, shops and wholesalers

Individual quote

depends on the number of controllers ordered

  • for installation companies and resellers
  • ET1 controller with a full set of sensors
  • materials and technical support

Patent-protected solution

Partners

Let's work together

We welcome installers, wholesalers and manufacturers as partners. Terms are agreed individually and depend on the number of controllers ordered.

Installers

Do you install hot water systems? Offer ET1 to your customers on wholesale terms, with technical support during installation.

Wholesalers and shops

Add the ET1 controller to your range. We will prepare terms matched to your order volumes.

Manufacturers

Do you make boilers, cylinders, pumps or other heating equipment? Let's talk about working together on ET1.

Technical support

Documentation and information for installers

Where should the flow sensor be installed?
  • On the cold water supply of the hot water appliance (cylinder, combi boiler, heat exchanger) whose circulation the controller manages.
  • Upstream of the sensor: a shut-off valve, a filter and a non-return valve.
  • A straight pipe section of at least 5 DN before the sensor and 3 DN after it.
  • In line with the water flow direction and the markings on the body. Any position: vertical, horizontal or in between.
  • So that the electronics are not exposed to moisture and the body is not exposed to stress from the pipework.
How do I install the sensor body?

The body has 2 tapered ¾" male threads - seal them using any method that gives a tight joint. Use tools that will not damage the brass body. Once the body is installed, fasten the electronic sensor with two M3 screws.

Make sure no thread sealant gets inside the sensor or the filter - this can slow down the controller's response.

How do I connect the controller cables?

On the bottom of the housing there is a 230 V switch, an F 1.6 A fuse and 5 cables:

  1. 230 V power supply - plug into a socket.
  2. 230 V circulation pump supply - connect as instructed by the pump manufacturer.
  3. Flow sensor (sensor flow) - mount on the flow sensor body.
  4. Circulation temperature sensor - mount on the circulation branch.
  5. Current / limit temperature sensor - mount in the hot water heating appliance.
How do I connect the circulation pump?

The controller comes with factory-connected cables. Before connecting it to the mains, connect the marked cable to the circulation pump supply (following the pump manufacturer's instructions), stripping the insulation from the wire ends first. The maximum pump output load is 150 VA.

Installation should be carried out by a suitably qualified person and confirmed with an entry in the warranty card.

What circulation temperature should I set?

The range is 30-50°C, factory setting 38°C, hysteresis 1°C. Example: at 38°C with 1°C hysteresis the pump will start (after flow is detected) when the temperature drops below 37°C. For poorly insulated or long pipework, set a longer pump run time or a higher circulation temperature.

Maintenance

At least once a year check the condition of the device and that the cables are connected correctly. Unplug the controller during thunderstorms - lightning can damage it.

24months

Manufacturer's warranty

KOCIOŁEK C.O. of Lublin, Poland, provides a 24-month warranty for correct operation of the controller, from the date of purchase. Complaints are processed within 30 days. The warranty requires installation by a suitably qualified person, confirmed with an entry in the warranty card.

Warranty terms (PL)
Type of message

The message is sent directly from this website. We do not store form data in any database.

Contact and partnership

Let's talk about ET1

Want to buy the controller, install heating systems or run a shop or wholesale business? Write or call us. We speak Polish and English.