Hot water circulation controllers

How much does 24/7 hot water circulation cost?

Measurement

A circulation pump running non-stop seems harmless - it only draws a few dozen watts. The real cost, however, is the heat that escapes from the pipes around the clock. We checked this in practice by measuring gas consumption in an ordinary house.

The building

A three-storey semi-detached brick house. Double-leaf cavity wall, insulated externally with 10 cm of polystyrene. The tested system serves 2 floors.

The circulation system

Measurement conditions

The measurement lasted 24 hours (15-16 August 2015) with no hot water drawn at all - we measured only the losses from the circulation loop cooling down. Outdoor temperature: +29°C during the day and +19°C at night. Cylinder set temperature: 60°C, reheating after a 5°C drop.

TimeEventGas meter reading
9:45start of test, cylinder heated to 60°C4799.251 m³
11:15first boiler start (reading after reheating)4799.631 m³
18:30reading4799.999 m³
23:10reading4800.315 m³
7:30reading4800.946 m³
9:45end of test4800.946 m³

Result

In 24 hours the system used 1.695 m³ of gas just to keep the circulation loop at 60°C - without the tap being turned on even once.

At the price at the time of the measurement (approx. PLN 2 per m³) that is 1.695 m³ x PLN 2 x 365 days, or approx. PLN 1,240 a year. Bear in mind that the measurement was taken in summer - in winter, when the pipes are surrounded by colder air, losses are usually higher.

Calculate it for your gas price

Cost of 24/7 circulation from our measurement: - a year (- a month).

The result applies to the system from our measurement. In your home, losses depend on the length and insulation of the pipes, the water temperature and where the pipes run.

How can these losses be reduced?

The ECOTECHNIK ET1 circulation controller starts the pump only when the flow sensor detects a water draw and the temperature in the circulation loop is below the set value. When nobody is using hot water, the pump stays off and the water in the pipes is not heated unnecessarily. You gain twice: hot water reaches the tap quickly, and heat losses are limited to the time when you actually use it.

See how the ECOTECHNIK ET1 circulation controller works.

Watch the film Buy now